Compatible with the Smart Aligner Android application for the generation of site close out reports including antenna alignment results from Multiwave tools and line sweep results. This PC based post-processing software efficiently manipulates line sweep and PIM traces for reporting purposes. It works with many of our Handheld RF Instruments. The Wireless Remote Tools software allows users to wirelessly monitor and control a wide range of Anritsu handheld RF instruments. Wireless Remote Tools provides a solution for the times when it is not practical to be close to the instrument.
Instructor Led Training. EasyTest Tools. Handheld Firmware Update Method. Indoor Mapping with Anritsu Handheld Analyzers. Interference Mapping. Line Sweep Tools. Home Test and Measurement Products. Request Quote. Overview Applications Options Library Overview.
Option Description. Brochure Brochure. What happens if the battery of my site master is completely discharged? If a battery is allowed to totally discharge, the smart-memory capability of the battery m ay be lost, resulting in incorrect battery capacity readings or loss of communication w ith the battery.
The NiMH battery will last longer and perform better if allowed to completely discharge b efore recharging. For maximum battery life, it is recommended that the NiMH battery be c ompletely discharged and recharged once every three months. There is a rack mount kit available for current models of handheld instruments.
The part number is Select the files to copy in the top window and the location for the files to be copied to in the bottom window. The Copy submenu and Copy dialog box are displayed picture below.
Select the file s to copy. NOTE: Press again to de-select if you choose not to copy the file. The file will be outlined in blue. Repeat with all the files to copy. To display files in a folder, select the folder and press the Enter key. Basically, the top window src is where you copy from and the bottom dst is where those files are going to. Brochure pdf 1.
Product Information, Compliance, and Safety for Anritsu Handheld Instruments This guide provides important notices, warranty, safety, and regulatory compliance information for Anritsu RF and microwave handheld analyzers. Site Master S3xxE - Help Help is a compilation of user documentation for easier viewing and navigation.
Leaflet pdf 3. Installation, Maintenance and Optimization Solutions Leaflet A small 2 page flyer to showcase the right tools needed to achieve best in class network reliability.
Installation, Maintenance and Optimization Solutions Brochure Discover Anritsu's best-in-class tools which will help your technicians and engineers optimize all areas of your network and elevate your network reliability to best-in-class. Drivers Software Downloads exe Drivers Software Downloads pdf Updating Anritsu Handheld Instrument Firmware This document provides an overview of the firmware update process.
How do I turn it off? I saved my measurements as a JPEG and a. DAT file. How do I view them on my SE? What is a Z calibration? Is there any recommendation for Battery Life on a Site Master? Is there a rack mount kit available for handheld instruments?
How do I copy files from my internal memory to my USB memory stick? An alternative to the Menu key is to press Shift, then the Mode 9 key to display the Mode Selector list box. Page 19 Instrument Overview Instrument Front Panel User-Created Shortcuts To create a shortcut to any submenu key or main menu key, press and hold the key until a grid appears, showing the open locations on the Menu screen where you can place the new shortcut.
Page Interface Screen Interface Screen Instrument Overview Interface Screen Figure Figure illustrate the Site Master interface screen in Cable and Antenna mode and Spectrum Analyzer mode, with touch screen menu keys, title bar, and measurement settings and results around the graph area, or sweep window. Figure Page Touch Screen Keys Use only Anritsu-approved batteries, adapters, and chargers with this instrument.
Caution Anritsu Company recommends removing the battery for long-term storage of the instrument. The Shift key icon is displayed after the Shift key is pressed, and it remains displayed until another button is pressed.
Page Symbols And Indicators Instrument Overview Interface Screen Symbols and Indicators The following symbols, icons, and indicators convey the instrument status or condition on the display. The colors shown here are in the standard or default display mode. Table It is recommended if the instrument does not respond as expected when you press the touch screen. To return to normal touch entry mode, reboot the instrument turn power Off, then On.
See Figure on page The five status messages are described next. Page Data Entry Data Entry Instrument Overview Data Entry User input can be in the form of numeric values for instrument or measurement settings, selected values from a preset list, or alphanumeric text when entering file names, for example.
To view or change a parameter value, access the appropriate submenu by pressing one of the five main menu keys along the bottom of the interface screen, then navigating through the touch screen submenus. Page Text Entry Instrument Overview Data Entry Text Entry When an instrument function requires you to enter text, such as a name for a measurement or setup file you wish to save, a touch screen keyboard is displayed. Digits can be entered using the touch screen keyboard or the front panel keypad.
Use the directional arrow keys or the rotary knob to highlight the desired mode, then press Enter to switch to the selected application. The external power connector is used to power the unit and for battery charging. A green blinking LED near the Power button indicates that the instrument battery is being charged by the external charging unit. On the back of the case is a large storage pouch for accessories and supplies. To install the instrument into the soft carrying case: 1. The soft case has panel openings for the fan inlet and exhaust ports.
Do not block Caution the air flow through the panels when the unit is operating. K Site Master User Guide Select the Measurement Type Press the Measurement main menu key and select the appropriate measurement. Press the Marker main menu key. Press the Marker 1 2 3 4 5 6 submenu key and select the marker number 1 button using the touch screen. The underlined number on the Marker submenu key indicates the active marker. Press Shift, then Limit 6 to display the Limit menu.
Press Single Limit and then use the numeric keypad, the arrow keys, or the rotary knob to change the limit value and then press Enter. Press the Units submenu key and select m to display distance in meters or ft to display distance in feet.
Set Amplitude Reference Level and Scale 1. Press the Reference Level submenu key and use the arrow keys, rotary knob, or the keypad to change the reference level. Activate the selected limit line by pressing the On Off submenu key so that On is underlined. Selecting, Activating, and Placing a Marker 1. Press the Marker 1 2 3 4 5 6 submenu key and select the desired marker using the touch screen marker buttons. The File menu and its submenus allow you to save, recall, copy, and delete files in internal memory or an external USB flash drive.
Managing Files Press the Shift key, then the File 7 key on the numeric keypad to display the File menu. Page Save Files Managing Files File Management Save Files The submenu keys that are available for file management may vary with instrument options and measurement modes.
Save Measurement As The Save Measurement As submenu key provides a one-touch method of saving the current measurement data. Optionally, you can use the Quick Name keys to insert preset text strings into the file name.
Similarly to the Quick Name keys, the matrix gives field personnel a shortcut method to enter file names in compliance with carrier requirements, which may include file naming conventions related to site number, sector information, color coding, measurement type, termination device, or frequency information. If all matrix keys are already defined, proceed directly to Step 1.
To edit any matrix key, press and hold the key until the Edit Quick Name dialog opens. Figure on page To expand a folder and view its subfolders, press Enter or the Right arrow key.
Press Enter again or the Left arrow key to collapse the folder. Press the Scroll key to switch navigation control to the Dst destination pane. Alternatively, you can directly press a folder in the bottom pane to select it. Upon Save completion, the file name numerical suffix Save Measurement As increments by 1 and will be applied to the next Save.
See Figure Name Type Page System Menu Application If the self test fails when the battery is fully charged and the instrument is Self within the specified operating temperature, contact your Anritsu Service Test Center and report the test results. Application Self Test: This key initiates a series of diagnostic tests related to the performance of the instrument for specific applications.